2. Sensor O2 tương thích với Model sau:
Maxtec MAX-1 O2 sensor for use with: Datex-Ohmeda® Excel 210-7800, Excel 7800, Modulus 4700, Modulus 7800, Modulus II 7810, Oxicap, 510, 051, 205, 125, 5100, 5120, 5125, 5140, 5125, 5200, 5250, 5250 RMG, 5400, 7200, 7800, 7810 Vent, S5172802; Envitec, Draeger; Hamilton Medical; Mercury Medical MSA; Pacifitech; Teledyne #C-41131; VTI; Viamed

3. Sensor O2 tương thích với Model sau:
Maxtec MAX-10 O2 sensor for use with: Analytical Industries; Envitec; Datex Engstrom Modulus SE7900; Datex-Ohmeda® Excel 210-7900, Modulus SE1700, Smart Vent, S-5, Aespire, Avance, Airsys, Aestiva 3000; Maxtec; Nuova; Teledyne; Viamed

4. Sensor O2 tương thích với Model sau:
Maxtec MAX-11 O2 sensor for use with: Draeger Narkomed 1A, 2, 2B, 3, 4, 6000, Babylog 8000, Savina, SA2 Anaesthesia Mach, Evita, Evita 2, Evita 4, Evita 2 Dura, Fabius, Fabius GS, Oxydig, Oxycom 100 D, PM8030, I-8000, Incubator 8000IC, Anemone; Datex-Ohmeda®; Envitec; Hamilton; Maxtec; Teledyne #C-61339, Viamed R-23V

5. Sensor O2 tương thích với Model sau: Maxtec MAX-12 O2 sensor for use with: Analytical Industries; Bird Avea Ventilator; Citi Technologies; Envitec; EME Hamilton Medical Viasys Arabella, Galileo, Raphael, Aladdin, 51254; Emerson Infant Flow; Datex-Ohmeda®; Hamilton Instruments Galileo, Raphael, Arabella, Multinex, Analyser; Infrasonics Adult Star 601T; Maxtec; MSA; Nuova; Puritan Bennett NP 840 Ventilator 4-074925-00; Siemens Servo 900C, 900D, 900E, Servo 300, 300A, SV 300, Servo 700, 710, SV900, V710, C/D, 9000, Infinity Delta; Spacelabs Capnograph; Taema Cesar 2, Horus; Teledyne TED 160, TED 190; and Viamed

6. Sensor O2 tương thích với Model sau:
Maxtec MAX-12A O2 sensor for use with: Air Shields Isolette; Analytical Instruments; City Technologies; Criticare 8100 Poet, 8500 Poet; Envitec; Datex-Ohmeda® Centiva S/5; Hamilton Galileo, Raphael, Arabella, Multinex Analys; Hudson RCI; Maxtec; Nuova; Taema Cesar (new); Teledyne; Viamed

7. Sensor O2 tương thích với Model sau: Maxtec MAX-13 O2 sensor for use with: Bird Products 6400, 8400, VIP Vent, Sentry; Envitec; Datex Engstrom Elvira, Erica; Datex-Ohmeda®; Hamilton; Hudson; Maxtec; MSA Mini-Ox I-III; Nuova; Puritan Bennett PB 850, 7820 Monitor, 7200 Ventilator; Respironics Esprit Ventilator Lifecare; Taema Eole, Cesar; Teledyne; Viamed.

8. Sensor O2 tương thích với Model sau:
Maxtec MAX-17 O2 sensor for use with: Analytical Industries; City Technologies; Envitec; Datex-Ohmeda®; Hamilton; Hudson RCI; Maxtec; MSA; Nuova; Sechrist Industries 650 Ventilator 43170; Teledyne TED 60J, TED 60T, TED 191T, TED 200T, TED 200T7; Viamed

9. Sensor O2 tương thích với Model sau:
Maxtec MAX-18 O2 sensor for use with: Analytical Industries, Envitec, Hudson RCI 5525, 5528, 5529, 5550, 5552; Maxtec, MSA, Nuova, Teledyne, Viamed

10. Sensor O2 tương thích với Model sau:
Maxtec MAX-19 O2 sensor for use with: Analytical Industries; Deversified Diagnostics Xenematic; Envitec; Hamilton Veolar, Amadeus, Aladdin; Heyer Pocket O2; Hudson RCI 5525, 5528, 5529, 5550, 5552; Maxtec; MSA; Nuova; Taema KV050501,Oxy 2100; Teledyne TED 160, TED 190; Viamed

11. Sensor O2 tương thích với Model sau: Maxtec MAX-7 O2 sensor for use with: Analytical Industries; City Technologies; Envitec OxiQuant M; Maxtec; MSA Mini-OX3000; Nuova; Siare Morpheus; Taema Alys, Clarys, YR010100; Stephan Artec; Teledyne TED AX 300; Viamed

12. Sensor O2 tương thích với Model sau:
Maxtec MAX-9 O2 sensor for use with: Analytical Instruments; Hudson RCI 6477, 5577, 5584, 5590, 5595; Maxtec; MSA; Nuova; Teledyne #B 39636; Viamed